- billingsmt.gov
- Services
- Building
- Codes & Information
- Design Criteria
Design Criteria
Type |
Requirements |
---|---|
Multifamily and Commercial |
Design per IBC 2018 |
One and Two Family Dwellings |
Design per IRC 2018 |
Seismic Zone |
Residential: "A" Multi-Family and Commercial: use Code Central Seismic Design Parameters version 3.10 |
Wind Load - Exposure "C" (3-second gust in miles per hour) |
Risk Category I: 100 MPH Risk Category II: 110 MPH Risk Category III: 115 MPH Risk Category IV: 120 MPH Residential: 115 MPH |
Foundation Depth |
36 in. frost depth - to top of footings |
Roof Snow Load |
Minimum design roof snow load after allowed reductions shall be 30 psf (i.e. Pf = 30 psf) For drift / unbalanced loading: Pg = 33 |
International Energy Conservation Code 2012 (IECC)
Structure |
Default Values |
---|---|
Ceilings |
R - 49 |
Walls |
R - 21 or R - 13 + 5 Continuous |
Floor over unheated space |
R - 30 |
Crawl Space walls |
R - 15 - Continuous |
|
R - 19 - Framed |
Basement walls |
R - 15 - Continuous |
|
R - 19 - Framed |
Windows |
U - 0.32 |